Indoor humidity by outdoor temperature: build a room-specific chart
A fixed winter humidity chart can be a useful prompt, but it cannot know how cold your glass edge, frame, reveal or exterior wall becomes. This tool turns indoor temperature, current RH, outdoor temperature and a surface preset into a seasonal planning table for your room.
There is no universal outdoor-temperature RH target
The same 45% room RH can leave a modern warm surface comfortable while pushing an older or poorly performing surface toward high local RH. Use the table as a comparison model, then measure the real coldest surface when the decision matters.
How to use the table
| Step | What to do | Why it matters |
|---|---|---|
| 1. Use paired readings | Enter indoor temperature and RH from the same place and moment. | Relative humidity changes with temperature; an unpaired percentage is easy to misread. |
| 2. Match the cold surface | Choose the closest preset, or use the full Lab if you can measure the surface directly. | Surface performance changes the seasonal ceiling more than a generic chart can show. |
| 3. Watch the direction | Compare warmer and colder outdoor rows instead of treating one row as a permanent setpoint. | The model shows how less outdoor cold generally leaves more surface-temperature margin. |
| 4. Verify the coldest spot | Check edges, frames, reveals, corners and areas behind furniture. | Center-surface estimates can miss colder local bridges. |
Why the modeled ceiling can differ from general humidity guidance
The table asks a narrow building-physics question: what room RH would correspond to about 80% RH at this modeled surface? General indoor-air guidance asks a broader question. EPA guidance says indoor RH should stay below 60% and ideally around 30–50% where possible, while also emphasizing moisture-source control and drying wet materials.
That means a modeled ceiling above 60% is not a recommendation to add moisture. Use the more conservative practical limit, and do not lower humidity blindly when comfort, static electricity or very dry indoor air are concerns.
What the chart cannot diagnose
Leaks and wet materials
Air RH does not locate a plumbing leak, roof leak, groundwater path or hidden wet assembly.
Mold or health effects
The calculator does not identify growth, species, exposure or a medical cause.
Exact window performance
Preset values are simplified. Spacer, frame, installation and airflow can dominate the coldest local point.
Ventilation performance
A seasonal RH table does not test exhaust flow, pressure balance or whether replacement air reaches the room.
Sources and method
US EPA — Mold, Moisture and Your Home
General indoor RH and moisture-source guidance. Read the EPA guide.
Home Moisture Lab methodology
Magnus dew-point approximation, surface-RH calculation, surface presets and reverse humidity limits. Review formulas and assumptions.
Need measured-surface input or room history?
The full Lab accepts a measured surface temperature, compares several rooms, tests what-if RH changes and stores snapshots locally in your browser.